Sherwin-williams concrete floor coating products

I have a variety of some Sherwin Williams concrete coatings. These could all be used in conjunction with each other to finish a garage/shop floor. **This is not a complete kit, other items would need to be purchased separately** List below: Fastop 4100 B – 3 x 69 fl oz cans. **make an offer** General Polymers (Resuprime) 3579 A – 4 x 1 gal cans. **make an offer** General Polymers (Resuflor) 3561 A – 2 x 1 gal cans. **make an offer** Resutile 4700 Instant A – 2 x 1 gal cans **make an offer** $500 obo takes all

Concrete sealer interior floor sealer water based acrylic sealer 1 gallon

UBQ Industries – Active Elements™ Advance Seal – Interior Concrete Floor SealerWater based acrylic sealer for interior concrete floors • 1 GallonActive Elements™ – Advance Seal is a water-reducible acrylic emulsion based on hard polymers with ultra-small particle size that gives the coating excellent substrate penetration and durability. The material has excellent UV stability and will not chalk or yellow. Advance Seal is the perfect solution for interior floors where depth of color and moderate gloss is desired. For added protection on high traffic floors, Advance Seal can be top coated with Active Elements – Protect & Shine to form a sacrificial barrier.Coverage – 100-200 square feet per gallon Coverage variations depend on concrete surface porosity and amount of material applied. Surface Preparation Concrete must be clean and free of dirt, dust, oil, grease, mold and mildew, and any other contaminants. Acid Stained concrete must be neutralized, thoroughly cleaned, and dry prior to sealing. Pigment stained concrete must be completely dry prior to sealing.Bare concrete and overlays must be open and porous to allow for sealer penetration. All new concrete should be allowed to cure for a minimum of 45 days, or until a pH reading of 10.5 or less is achieved. Concrete must be completely dry prior to sealer application. It is strongly recommended that a surface probe moisture meter be utilized to verify the surface is dry. After visually determining the concrete is dry, test a minimum of 10 different areas of the concrete with the moisture meter. Pay special attention to cracks, control joints, and slab edges. Application – Roller Stir well before use. Pour Active Elements – Advance Seal through a strainer prior to use. Apply by using a high quality 3/8” nap lint free roller cover, or 1/4” nap mohair roller cover (for smooth surfaces). Dip directly into a roller pan and distribute the material by rolling laterally and then up and down (crosshatch rolling). Roll the material into a wet edge, and avoid excessive back rolling. When applying 2 coats of sealer roll the second coat perpendicular to the first. Keep containers closed when not in use, unattended open material will form a skin on the surface.Application – Sprayer ( HVLP or Airless) Stir well before use. Pour Active Elements – Advance Seal through a strainer prior to use. Spray using an airless or HVLP spray system. When applying 2 coats, spray the second coat perpendicular to the first. Always use a chemical respirator when spraying with an airless or HVLP spray system. Keep containers closed when not in use, unattended open material will form a skin on the surface.Drying Time Dry to touch: 30 minutes Dry hard: 55 minutes Recoat: 2 hours Light Foot Traffic: 4 hours Full Cure: 72 hours The listed dry times are for 75 degree (F) temperatures and medium humidity. Low temperatures and/or high humidity will slow drying and curing time. Clean Up Tools can be cleaned with soap and waterPerformance % solids by weight – 31% (ASTM D2369) 60 degree gloss – 100% (ASTM D523) Pencil Hardness – 4B (ASTM D3363) Flexibility – Greater than 32% elongation (the maximum for ASTM D522) Impact Resistance – 40 inch-lbs (ASTM D2794) Abrasion Resistance – Wear index of 0.248, CS17 wheels, 1000g load (ASTM D4060) Chemical Resistance – 1 hour spot test (ASTM D1308) Water – No softening, blistering, flaking or discoloration Detergent– No softening, blistering, flaking or discoloration Dilute Base (pH13) – No softening, blistering, flaking or discoloration Dilute Acid (pH2) – Discoloration, but no softening, blistering or flaking Gasoline– No softening, blistering, flaking or discoloration Motor Oil– No softening, blistering, flaking or discoloration Red Wine– No softening, blistering, flaking or discoloration Ketchup – No softening, blistering, flaking or discoloration Mustard– Discoloration, but no softening, blistering or flaking *Performance testing conducted by an independent laboratory. Limitations· Interior use only· This product may only be used on fully cured concrete. · Not suitable for flooring that is exposed to harsh chemicals. · Air and substrate temperatures must be at least 40°F and rising.Storage and Shelf Life Do not allow to freeze. Shelf life of unopened product is approximately one year. Slip and Fall Precautions OSHA and the American Disabilities Act (ADA) have now set enforceable standards for slip-resistance on pedestrian surfaces. The current coefficient of friction required by ADA is .6 on level surfaces and .8 on ramps. UBQ Industries, LLC recommends the use of angular slip-resistant aggregate in all coatings or flooring systems that may be exposed to wet, oily or greasy conditions. It is the contractor and end users’ responsibility to provide a flooring system that meets current safety standards. UBQ Industries, LLC or its sales agents will not be responsible for injury incurred in a slip and fall accident.Moisture Vapor Emissions/Alkalinity Precautions All interior concrete floors not poured over an effective moisture vapor barrier/inhibitor are subject to possible moisture vapor transmission and related high levels of alkalinity that may lead to blistering and failure of the coating system. It is the coating applicator’s responsibility to conduct calcium chloride and relative humidity probe testing to determine if excessive levels of vapor emissions or alkalinity are present before applying any coatings.Warranty The Manufacturer and/or the Seller warrants that if any goods supplied prove defective in workmanship or material, that Manufacturer and/or Seller shall replace them or refund the purchase price. This warranty is made in lieu of any and all other warranties expressed or implied. Before application, the User shall determine the suitability of the product for his intended use and User assumes all risks and liabilities whatsoever in connection therewith. Under no circumstances shall the Manufacturer and/or Seller be liable for incidental, consequential or other damages for alleged negligence, breach of warranty, or strict liability arising out of use or handling of this product. The sole liability of Manufacturer and/or Seller for any claims arising out of the use or sale of the product shall be for the User’s purchase price. Any claim of defective product must be received in writing within one (1) year from date of shipment. DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN.

Concrete sealer for interior floors water based acrylic sealer 5 Gallon (515)

Normal 0 false false false EN-US JA X-NONE UBQ Industries – Active Elements™ Advance Seal Water based acrylic sealer for interior concrete floors.Active Elements™ – Advance Seal is a water-reducible acrylic emulsion based on hard polymers with ultra-small particle size that gives the coating excellent substrate penetration and durability. The material has excellent UV stability and will not chalk or yellow. Advance Seal is the perfect solution for interior floors where depth of color and moderate gloss is desired. For added protection on high traffic floors, Advance Seal can be top coated with Active Elements – Protect & Shine to form a sacrificial barrier.Coverage – 100-200 square feet per gallon Coverage variations depend on concrete surface porosity and amount of material applied. Surface Preparation Concrete must be clean and free of dirt, dust, oil, grease, mold and mildew, and any other contaminants. Acid Stained concrete must be neutralized, thoroughly cleaned, and dry prior to sealing. Pigment stained concrete must be completely dry prior to sealing.Bare concrete and overlays must be open and porous to allow for sealer penetration. All new concrete should be allowed to cure for a minimum of 45 days, or until a pH reading of 10.5 or less is achieved. Concrete must be completely dry prior to sealer application. It is strongly recommended that a surface probe moisture meter be utilized to verify the surface is dry. After visually determining the concrete is dry, test a minimum of 10 different areas of the concrete with the moisture meter. Pay special attention to cracks, control joints, and slab edges. Application – Roller Stir well before use. Pour Active Elements – Advance Seal through a strainer prior to use. Apply by using a high quality 3/8” nap lint free roller cover, or 1/4” nap mohair roller cover (for smooth surfaces). Dip directly into a roller pan and distribute the material by rolling laterally and then up and down (crosshatch rolling). Roll the material into a wet edge, and avoid excessive back rolling. When applying 2 coats of sealer roll the second coat perpendicular to the first. Keep containers closed when not in use, unattended open material will form a skin on the surface. Application – Sprayer ( HVLP or Airless) Stir well before use. Pour Active Elements – Advance Seal through a strainer prior to use. Spray using an airless or HVLP spray system. When applying 2 coats, spray the second coat perpendicular to the first. Always use a chemical respirator when spraying with an airless or HVLP spray system. Keep containers closed when not in use, unattended open material will form a skin on the surface.Drying Time Dry to touch: 30 minutes Dry hard: 55 minutes Recoat: 2 hours Light Foot Traffic: 4 hours Full Cure: 72 hours The listed dry times are for 75 degree (F) temperatures and medium humidity. Low temperatures and/or high humidity will slow drying and curing time. Clean Up Tools can be cleaned with soap and water Performance % solids by weight – 31% (ASTM D2369) 60 degree gloss – 100% (ASTM D523) Pencil Hardness – 4B (ASTM D3363) Flexibility – Greater than 32% elongation (the maximum for ASTM D522) Impact Resistance – 40 inch-lbs (ASTM D2794) Abrasion Resistance – Wear index of 0.248, CS17 wheels, 1000g load (ASTM D4060) Chemical Resistance – 1 hour spot test (ASTM D1308) Water – No softening, blistering, flaking or discoloration Detergent– No softening, blistering, flaking or discoloration Dilute Base (pH13) – No softening, blistering, flaking or discoloration Dilute Acid (pH2) – Discoloration, but no softening, blistering or flaking Gasoline– No softening, blistering, flaking or discoloration Motor Oil– No softening, blistering, flaking or discoloration Red Wine– No softening, blistering, flaking or discoloration Ketchup – No softening, blistering, flaking or discoloration Mustard– Discoloration, but no softening, blistering or flaking *Performance testing conducted by an independent laboratory. Limitations· Interior use only· This product may only be used on fully cured concrete. · Not suitable for flooring that is exposed to harsh chemicals. · Air and substrate temperatures must be at least 40°F and rising. Storage and Shelf Life Do not allow to freeze. Shelf life of unopened product is approximately one year. Slip and Fall Precautions OSHA and the American Disabilities Act (ADA) have now set enforceable standards for slip-resistance on pedestrian surfaces. The current coefficient of friction required by ADA is .6 on level surfaces and .8 on ramps. UBQ Industries, LLC recommends the use of angular slip-resistant aggregate in all coatings or flooring systems that may be exposed to wet, oily or greasy conditions. It is the contractor and end users’ responsibility to provide a flooring system that meets current safety standards. UBQ Industries, LLC or its sales agents will not be responsible for injury incurred in a slip and fall accident.Moisture Vapor Emissions/Alkalinity Precautions All interior concrete floors not poured over an effective moisture vapor barrier/inhibitor are subject to possible moisture vapor transmission and related high levels of alkalinity that may lead to blistering and failure of the coating system. It is the coating applicator’s responsibility to conduct calcium chloride and relative humidity probe testing to determine if excessive levels of vapor emissions or alkalinity are present before applying any coatings.Warranty The Manufacturer and/or the Seller warrants that if any goods supplied prove defective in workmanship or material, that Manufacturer and/or Seller shall replace them or refund the purchase price. This warranty is made in lieu of any and all other warranties expressed or implied. Before application, the User shall determine the suitability of the product for his intended use and User assumes all risks and liabilities whatsoever in connection therewith. Under no circumstances shall the Manufacturer and/or Seller be liable for incidental, consequential or other damages for alleged negligence, breach of warranty, or strict liability arising out of use or handling of this product. The sole liability of Manufacturer and/or Seller for any claims arising out of the use or sale of the product shall be for the User’s purchase price. Any claim of defective product must be received in writing within one (1) year from date of shipment. DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN.

Glossy sealer and protector for concrete floors

• Polished concrete floors. Apply evenly to clean, dry concrete using a sprayer or microfiber applicator. Allow the product to penetrate and react with the surface, then remove any excess residue. Can be used on new or existing concrete.

Concrete sealer clear wet look solvent based exterior garage floors 5 Gallon

UBQ Industries – Active Elements™ True Seal 400SSolvent Based Exterior Concrete Sealer – 400VOC – 5 gallon pail*****NOT available in California and Maricopa County, AZ******Active Elements TM – TrueSeal 400S is a high-quality, 400 VOC, solvent based sealer designed for decorative concrete projects. It is a tough acrylic methacrylate blended polymer that produces coatings with excellent gloss, stain-resistance and is easy to clean. Adhesion to properly prepared concrete surfaces is excellent and the material is non-yellowing. Active Elements – Solvent Seal 400S is fortified with a dual functioning HALS + UV absorber additive for maximum color protection. For next level protection from salt, chlorine and chemical attack; TrueSeal 400S contains a multifunctional silane additive to reject chemical attack and promote adhesion and cross-linking.Coverage 100-200 square feet per gallon – Coverage variations depend on concrete surface porosity and amount of material applied.Drying Time Dry to touch: 15-40 minutes Re-coat: 30-40 minutes Light Foot Traffic: 3 hours Heavy Traffic: 48-72 hours Dry times are for 75 degree (F) temperatures and medium humidity, lower temperatures will slow drying and curing time. Do not apply if rain is expected within 3 – 6 hours.Surface Preparation Concrete must be clean and free of dirt, dust, oil, grease, mold and mildew, and any other contaminants. Use our Degrease or Paint Strip for help with this.Acid stained concrete must be neutralized, thoroughly cleaned, and dry prior to sealing. Use our neutralize to help with this step. Pigment stained concrete must be completely cured prior to sealing.All new concrete should be allowed to cure for a minimum of 28-45 days, or until a pH reading of 10.5 or less is achieved. Concrete must be completely dry prior to sealer application. It is strongly recommended that a surface probe moisture meter be utilized to verify the surface is dry. After visually determining the concrete is dry, test a minimum of 10 different areas of the concrete with the moisture meter. Pay special attention to cracks, control joints, and slab edges. Application Tools Pump sprayer, Airless sprayer or Roller & Brush Thinning Scratch Coat – When applying to bare concrete, apply a “scratch coat” consisting of 1 part TrueSeal 400S & 1 part TrueSeal Thinner to ensure deep penetration and reduction of bubbling due to out-gassing. TrueSeal Thinner can be used to prepare the material for spray application. Add 1-2 quarts of TrueSeal Thinner per 1 gallon of sealer, based on thickness of coating desired.Preferred Method – Spraying When spraying, protect surroundings with masking paper, masking plastic, or spray shield. Always use a filter when pouring TrueSeal 400S into a sprayer. Use only high quality industrial grade solvent resistant spray equipment. Concrete surface temperature must be between 50 – 90 degrees (F). If rolling TrueSeal 400S, work material into a wet edge, and avoid excessive back rolling. When applying two coats, roll the second coat perpendicular to the first.Clean Up Tools can be cleaned with TrueSeal Thinner.Storage and Shelf Life Do not allow to freeze. Shelf life of unopened product is approximately one year. Keep away from heat, sparks & flame. Vapors may cause fire. Safety Always use appropriate safety equipment including but not limited to, goggles, face shield, rubber gloves, chemical resistant clothing or apron, and chemical respirator. For exterior use only. INHALATION: Vapors may cause dizziness, headaches, or nausea. Immediately move to fresh air. Seek medical attention. EYES: Contact with eyes can cause severe burning, irritation, and blurred vision. Flush with water. Seek medical attention. SKIN: May cause severe irritation and or chemical burns. Wash with soap and water. Seek medical attention. Keep out of reach of children.Use only with adequate ventilation.Keep away from heat, sparks & flame. Vapors may cause fire. Avoid prolonged contact with skin. Use only with adequate ventilation. Avoid breathing vapors or spray mist. Do not take internally. If swallowed, do not induce vomiting. Call physician immediately. Close container after use. It is the sole responsibility of the property owner or applicator to determine the suitability and safety of applying this product in areas of pedestrian traffic. LimitationsThis product may only be used on fully cured concrete. Allow a minimum of 28-45 days of cure time after the concrete is poured to allow ample time for the concrete to completely hydrate.Do not apply when air or surface temperature exceeds 90 degrees (F) or LAP marking / poor penetration / bubbling may result. Do not apply to wet or damp concrete, moisture will inhibit penetration of the sealer and cause improper curing, flaking or lifting of the sealer. Do not apply when it may rain, or if dew may condense on the surface before the sealer has cured. Allow for extended dry times during cold weather / high humidity. ProhibitionsSelected state and county jurisdictions prohibit or limit the use of solvent based products. Users should consult local guidelines before using this product.Slip and Fall PrecautionsOSHA and the American Disabilities Act (ADA) have standards for slip-resistance on pedestrian surfaces. The coefficient of friction required by ADA is .6 on level surfaces and .8 on ramps. UBQ Industries, LLC recommends the use of slip-resistant additives in all sealers or coatings that may be exposed to wet, oily or greasy conditions. It is the installer and end users’ responsibility to provide a flooring system that meets current safety standards. UBQ Industries, LLC or its sales agents will not be responsible for injury incurred in a slip and fall accident. WarrantyThis warranty is made in lieu of all other warranties, either expressed or implied. Before application the User shall determine the suitability of the product for his/her intended use and User assumes all risks and liabilities whatsoever in connection therewith. Neither seller nor manufacturer has any knowledge or control concerning the purchaser’s use of this product and no warranty is made as to the results of any use. The Manufacturer and/or Seller warrants that if any goods supplied prove defective in material the sole obligation shall be to replace said product. Any claim of defective product must be received in writing within one (1) year from date of shipment. Neither Manufacturer nor Seller shall assume any liability for injury, loss, or damage resulting from use of this product. DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN.

Official concrete floor sealer natural floor wax 5 lb easy to use

UBQ Industries – Active Elements™ London Wax Natural Floor Finish Wax Active Elements™ London Wax is an environmentally safe and friendly material using natural waxes derived from renewable resources. It is non-flammable, non-combustible and safe to use in any interior environment. Pleasant smelling and easy to use, London Wax an excellent choice for a low sheen sealer alternative. Use on: • Acid stained concrete • Integral colored concrete • Micro toppings • Plain grey concrete • Smooth masonry surfaces Highlights: •Natural Waxes from renewable sources • No petroleum based waxes • Breathable sealer • Natural antimicrobial properties • Simple application • Simple maintenanceCoverage: 500-1000 square feet per 5 LB can. Coverage variation is based on the texture and porosity of the floor. Tools needed: • Floor Machine – Low speed (175 rpm) • Bassine Brush • Union Mix Brush • Soft cotton cloth Surface Prep: Concrete must be clean and free of dirt, dust, oil, grease, mold and mildew, and any other contaminants. Acid stained concrete must be neutralized, thoroughly cleaned, and dry prior to waxing. Application: Apply roughly a quarter cup of wax directly to the floor. Set the floor machine with Bassine brush on top of the wax dollop. This prevents the wax from being flung away from the brush. Spread the wax to a uniform appearance being careful to not leave any ridges of wax behind. Repeat this process in small sections throughout the entire floor. Walls, corners and edges can be hand applied using a soft cotton cloth. Allow the wax to dry (approximately 20-40 minutes), you will notice the floor during initial application becomes very dark, when the color lightens up uniformly you may begin the buffing process. Or in some cases, such as rough floors you may wish to add a second coat to the floor prior to buffing. Once dry, buff the floor using a Union Mix brush. A nice low sheen gloss will develop immediately. Edges and corners that cannot be reached with the Union Mix brush can be hand buffed using a clean cotton cloth. OPTIONAL: To develop a slightly higher gloss the London Wax can be buffed using a high speed burnisher (1500-2000 rpm) using a pad designed for soft finishes. Maintenance: Dust mop using a microfiber pad, wet mop using Active Elements – Daily Clean neutral pH floor cleaner. Do not use harsh chemicals or cleaners on the waxed floor. Scuffs and marks can be buffed out using a soft cotton cloth. Dull spots can be fixed by hand applying additional wax and then buffing with a soft cotton cloth. Clean Up: Tools can be cleaned using mineral spirits. Need a BULK or custom order? Pallet quantities are our specialty. Just email us and we can work out the details with you.

Preencha seus dados e te redirecionamos para o WhatsApp da nossa equipe.

Não perca tempo (e dinheiro) com a tinta errada!

Sua indústria precisa de durabilidade e nós temos a técnica.

  • Preço direto de fábrica.
  • Consultoria técnica gratuita.
  • Qualidade ISO 9001.